You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Attempting to produce a factory.bin for the hardware identical devices D-Link DIR-810L and Trendnet TEW-810DR. In order to flash over the factory image, a short tag needs to be appended to firmware image. See the device pages:
[[]https://openwrt.org/toh/d-link/dir-810l?s[]=810l]
[[https://openwrt.org/toh/trendnet/trendnet_tew-810dr_1.0_1.1?s[]=tew&s[]=810dr]]
Both pages use a tool that is provided in both the D-Link and Trendnet GPL source download for the respective device.
I can confirm that one cannot flash over the factory image on the Trendnet without appended tag.
I found a prior mailing of someone needing to accomplish the same task and the respondent complained about the lack of documentation. The submitter wrote his own.
[[https://jmomo.net/files/lede/patch_sets/v16-0002-ipq806x-Add-support-for-new-device-tew827dru.patch]]
I attempted to use mkcameofw/cameofw in a git pull versioned to 19.07.1 and the build error out, unable to find tool mkcameofw/cameofw.
A couple of points:
mkcameofw seems to be broken and unused. Both the device pages
describe the use of GPL'd ncc_att_hwid after the build for the initial
install.
I've searched for the documentation for ncc_att_hwid and cameo
signature and only came up with it being applied in OpenWRT/DD-wrt.
Users are working around the broken code manually.
ncc_att_hwid is GPL'd and could be included in the build tree.
The respective cameo signatures can be seen in the hex output of the D-Link and Trendnet firmware.
If the project could either adapt ncc_att_hwid or the previously submitted tool, factory flash bins could be produced for several devices.
The text was updated successfully, but these errors were encountered:
shep971:
Attempting to produce a factory.bin for the hardware identical devices D-Link DIR-810L and Trendnet TEW-810DR. In order to flash over the factory image, a short tag needs to be appended to firmware image. See the device pages:
[[]https://openwrt.org/toh/d-link/dir-810l?s[]=810l]
[[https://openwrt.org/toh/trendnet/trendnet_tew-810dr_1.0_1.1?s[]=tew&s[]=810dr]]
Both pages use a tool that is provided in both the D-Link and Trendnet GPL source download for the respective device.
I can confirm that one cannot flash over the factory image on the Trendnet without appended tag.
I found a prior mailing of someone needing to accomplish the same task and the respondent complained about the lack of documentation. The submitter wrote his own.
[[https://jmomo.net/files/lede/patch_sets/v16-0002-ipq806x-Add-support-for-new-device-tew827dru.patch]]
I attempted to use mkcameofw/cameofw in a git pull versioned to 19.07.1 and the build error out, unable to find tool mkcameofw/cameofw.
A couple of points:
mkcameofw seems to be broken and unused. Both the device pages
describe the use of GPL'd ncc_att_hwid after the build for the initial
install.
I've searched for the documentation for ncc_att_hwid and cameo
signature and only came up with it being applied in OpenWRT/DD-wrt.
Users are working around the broken code manually.
ncc_att_hwid is GPL'd and could be included in the build tree.
The respective cameo signatures can be seen in the hex output of the D-Link and Trendnet firmware.
If the project could either adapt ncc_att_hwid or the previously submitted tool, factory flash bins could be produced for several devices.
The text was updated successfully, but these errors were encountered: