FS#2657 - Failsafe mode dosn't work on MikroTik (RB750r2, RB951Ui-2HnD) #8462

Closed
openwrt-bot opened this issue Dec 7, 2019 · 0 comments
Closed
Labels

Comments

@openwrt-bot
Copy link

jbotz:

Supply the following if possible:

  • Device problem occurs on: MikroTik RB750r2, RB951Ui-2HnD
  • Software versions of OpenWrt/LEDE: 18.06.5 fresh install

So I have several of both of these devices, and I can't seem to do
boot to failsafe on them. After some initial difficulties I tried
some experiements with freshly flashed systems...

  1. If I try the "wait for the 5Hz flashing LED then press button"
    method, it goes to 10Hz flashing and never stops... never responds
    to pings on 192.168.1.1.

  2. If I try the "watch for message on network with tcpdump"
    method, no such message appears. Here I've tried both WAN and LAN
    ports, and used tcpdump with and without filters (without filters
    I see a bunch of stuff, but not the "please press button now"
    message).

The above holds for both types of boxes. They work fine otherwise,
for basic as routers/access points.

I'd be happy to more testing... I have ar least one 750r2 that's not
in service.